For on-site calibrations
Humidity Standards
inexpensive on-site calibration
simple and safe to use
unlimited storage life
On-site calibration and adjustment of Rotronic probes.
With the humidity standards, a calibration device and HW4 software running on a PC, calibration is easily achieved. It is also possible to calibrate and adjust probes using the handheld instrument HygroPalm23-A.
Third-party probes can also be calibrated.
- Ampoules contain unsaturated salt solutions
- Inexpensive calibration on site
- Simple and safe use
- Unlimited lifetime
- Practical packs of 5 ampoules of the same humidity value (approx. 0.8 ml per ampoule)
AVAILABLE STANDARDS |
|||||
Humidity Value |
Uncertainty at 23 °C |
Order Code |
|||
0.5 %rh |
±0.3 %rh |
EA00-SCS |
|||
5 %rh |
EA05-SCS |
||||
10 %rh |
EA10-SCS |
||||
11 %rh |
EA11-SCS |
||||
20 %rh |
EA20-SCS |
||||
35 %rh |
±0.5 %rh |
EA35-SCS |
|||
50 %rh |
±0.9 %rh |
EA50-SCS |
|||
60 %rh |
EA60-SCS |
||||
65 %rh |
EA65-SCS |
||||
75 %rh |
EA75-SCS |
||||
80 %rh |
±1.2 %rh |
EA80-SCS |
|||
95 %rh |
EA95-SCS |
The calibration devices from Rotronic are small, airtight chambers which precisely fit Rotronic probes.
The humidity standard is poured on to an absorbent textile pad in the lower part of the device. The specified humidity is generated in the calibration device. After a stabilisation period, the probe can be calibrated or adjusted against the traceable value of the humidity standard.
TYPICAL ACCESSORIES |
||
Push-on calibration devices |
||
Push-on calibration deviceØ 14…15 mmER-15 Gasket with O-ring and thumb screw. For 1 probe. Brass, nickel-plated. |
||
Push-on calibration deviceØ 14…15 mmEDM 15/15 Gasket with O-ring and thumb screw. For 2 probes. Brass, nickel-plated. |
||
Push-on calibration deviceØ 20 mmER-20K Gasket with O-ring and thumb screw. For 1 probe, Brass, nickel-plated. |
||
Push-on calibration deviceØ 15..15 mm
ERV-15 Gasket with O-ring and thumb screw. For 1 probe. Vertical calibration position. Brass, nickel-plated. |
||
Push-on calibration deviceØ 4…5 mmER-05 Gasket with O-ring and thumb screw. For 1 probe. Brass, nickel-plated. |
||
Push-on calibration deviceØ 12 mmER-12K Gasket with O-ring and thumb screw. For 1 probe. Brass, nickel-plated. |
||
Screw-on calibration devices |
||
Screw-on calibration deviceØ 25 mm (PG11)EM-25 Gasket with seal face on probe. Cannot be used for HC2-S probes. For 1 probe. Brass, nickel-plated. |
||
Screw-on calibration device(1/2"G / 1/2"NPT)EM-G Gasket with seal face on probe. Cannot be used for HC2-S probes. For 1 probe: probe types E / HP / IE. Brass, nickel-plated. |
||
Screw-on calibration device, Ø 25 mm (PG11)EMV-25 Gasket with seal face on probe. Cannot be used for HC2-S probes. For 1 probe. Vertical calibration position. Aluminium, anodised. |
||
Calibration devices for specialised probes |
||
Calibration devices for all sword probesEGS Calibration device for all sword probes. Aluminium, anodised. |
||
Water Activity Sample HolderWP-14-S For water activity probes: HC2-AW, HC2-AW-USB, AW-DIO |
CALCULATORS AND CONVERSION CHARTS:
TECHNICAL BULLETINS:
Explanation of relative humidity
DATASHEET:
Humidity standards for rh probes datasheet
Safety datasheet for humidity standards