Oil in water monitor for on-line use in safe areas
SA-100-1000
laser induced UV fluorescence
patented ultrasonic cleaning
zero routine maintenance
Side stream/slip stream on-line oil in water analyser.
The SA series of on-line oil in water monitors provide accurate and continuous measurements of water pollution and are designed for industrial use in areas that do not require a hazardous area certification.
These systems meet IMO requirements for bilge discharge monitoring and do not require cleaning fluids, reagents or other consumables. The patented ultrasonic cleaning maintains the system without operator intervention, enabling a very low cost of ownership.
The updated software allows for remote control and monitoring, making these systems ideal for un-manned locations.
Download Oil in water product range brochure
GENERAL |
||||
Measurement |
Oil in water |
|||
Measurement principle |
Laser induced UV fluorescence |
|||
Configuration |
Side stream (or bypass) flow |
|||
Range |
0 to 3,000 ppm |
|||
Cleaning |
Automatic ultrasonic |
|||
Accuracy |
± 1 % of measurement range |
|||
Repeatability |
> 99 % |
|||
Response time |
< 1 second, continuous results |
|||
Process temp. range |
0 to +100 °C |
|||
Ambient temp. range |
-20 to +50 °C |
|||
Display |
Interactive PC LCD touch screen |
|||
Certification |
||||
European |
CE marked |
|||
Ingress protection |
IP66 |
|||
IMO |
IMO certified |
|||
Shipping |
||||
Shipping weight |
Approx. 20 Kg excluding stand |
|||
MECHANICAL |
||||
Dimension |
42 cm (W) x 33 cm (H) x 22 cm (D) |
|||
Clear space |
45 cm front and rear |
|||
Mounting |
Optional stand or brackets |
|||
Material (wetted parts) |
316L SS |
|||
Enclosure |
316L SS |
|||
Pressure to cell |
0 to 15 BarG |
|||
Sample flow rate |
0 to 25 l/min |
|||
Process connection |
Standard threaded NPT (flanges optional) |
|||
Pipe diameter |
0.5" standard, options available |
|||
ELECTRICAL / UTILITIES |
||||
Power voltage |
110 or 230 VAC |
|||
Power frequency |
50 or 60 Hz/DC |
|||
Power consumption |
60 W normal, 300 W peak |
|||
Outputs |
||||
Current |
4 to 20 mA passive (modbus over HART optional) |
|||
Digital |
Ethernet |
|||
Wireless |
Wi-fi (optional) |
|||
Remote access |
VNC, master remote manager |
|||
Internal data storage |
> 10 years |
|||
Security |
Multiple level password protection |
|||
All specifications subject to change |
VIDEO:
Oil in water analysis - ultrasonic cleaning demonstration video
Oil in water technology overview
DATASHEET: