Dew point meter for use in hazardous areas
ExMa
3 self-configurable power modes
ATEX certified
integral flow control
4-20 mA, RS232 and 3 alarm outputs

A dew point meter for use in hazardous areas.
The ExMa is an explosion-proof dew point meter which can be installed in either indoor or outdoor applications. This cost-effective solution provides a complete on-line system, with built-in filtration, flow regulation and flow meter.
The ExMa can be configured to act as a loop powered transmitter or, when powered with either mains supply (90 to 260VAC) or a DC (12-24VDC), the outputs include 4-20 mA, RS232 and 3 alarm relays. The onboard display and user interface has through-glass touch user buttons for easy configuration in the field.
With an impressive measurement range of -110 °C to +20 °C dew point, this compact system offers fast, accurate and repeatable results.
GENERAL |
||||
Measurement |
°C and °F dew point, ppmV, ppmW, µB H2O vapour pressure, grams of H2O/m3 and Lbs H2O/106 standard cubic feet in natural gas. |
|||
Measurement principle |
Nanosensor Aluminium Oxide |
|||
Configuration |
On-line |
|||
Moisture range |
-110 to + 20 °C dew point |
|||
Temperature range |
-40 to + 70 °C |
|||
Pressure range |
2 to 1000 PSIA |
|||
Moisture accuracy |
±2 °C temperature corrected |
|||
Temperature accuracy |
±2 °C |
|||
Pressure accuracy |
±1 % |
|||
Resolution |
< 0.01 °C |
|||
Repeatability |
0.8 °C |
|||
Sample flow |
> 1 LPM |
|||
Response time |
95 % of step change in 3 min. |
|||
Process temp. range |
-20 to +60 °C |
|||
Ambient temp. range |
-40 to +85 °C |
|||
Certification |
||||
European |
CE marked |
|||
IP rating |
IP66 & IP68 |
|||
FM/CSA rating |
Class I, Div I, Groups B, C and D. Class II, III, Div 1, Groups E, F and G pending |
|||
ATEX |
ATEX 2 GD, Exd I & IIC. IECEX, Exd I & IIC pending |
|||
Calibration |
NIST traceable (NPL traceable option) |
|||
Shipping |
||||
Shipping weight |
2.5 Kg |
|||
MECHANICAL |
||||
Dimension |
226 L x 147 W x 147 H mm |
|||
Connections |
3/4" OD tube and 1/4" NPTF Inlet, 1/8" NPTF Outlet |
|||
Enclosure material |
Aluminium or optional 316 stainless steel, glass lens |
|||
Material (wetted parts) |
316L stainless steel and PTFE |
|||
Pressure |
Inlet 2000 psi, outlet 50 psi |
|||
ELECTRICAL / UTILITIES |
||||
Power voltage |
3 automatic detection, self configuring power modes. 1) 90 to 260 VAC 47 to 440 Hz. 2) 12 to 24 VDC 10 VA. 3) 4/20 mA loop-powered without display. |
|||
Outputs |
||||
Current |
Modes 1 or 2: RS-422 isolated, 4 to 20 mA sink or source with HART®, 3 alarm relays - 3A, 250 VAC contacts |
|||
All specifications subject to change |