Early detection of oil leaks and spills.

ID-223 Oil sheen sensor

mitigate risk of water pollution
minimal maintenance
2 field adjustable alarm points

Download a datasheetRequest a quoteCall us

 

The ID-223 Oil Sheen Detector from Leakwise can be installed in dry or wet sumps to detect oil leaks from above ground oil storage, and a range of other applications.

The ID-223 has three different models (ID-223/500, ID-223/2000, ID-223/2500) with range of detection from 40 to 2500 mm.

The ID-223 can detect as little as 0.3 mm layer of oil on water reliably, repeatedly, and without false alarms. It can also monitor on-line changes in oil layer thickness. The signal processor relays can initiate both local and remote alarms, as well as control. Continuous built-in diagnostics monitor sensor operations.

The ID-223's high frequency transmitter is mounted on a patented float built in a guiding cage, which maintains its position precisely at the liquid/air interface, despite fluctuations in the liquid level.

The ID-223 Oil Sheen Detector is used in conjunction with one of three controllers, depending on the application.

  • The PS-220 Controller is an analog signal processor and power supply in a NEMA 4 enclosure, and supports a single ID-220 Leakwise sensor.
  • The SLC-220 Digital Signal Processor for Multiple (2 / 4 standard, more in a network) ID-220 Series sensor support, with various output options, including relay, lights, 4-20 mA, LCD, Modbus in RS-232 and RS-485 communication, and cellular remote connectivity.
  • The WSP-220 Wireless communication – Point-to-Point data radio.

SPECIFICATIONS

Detection range

0.3 to 20 mm (0.01 to 0.8 in) of hydrocarbon on water or brine

Floating range

40 to 500 mm(1.6 to 19.7 in)

Water lateral velocity

~30 cm/sec (~11.8 in/sec) without a stiller; may be doubled with a stiller

Water temperature

0 to 70 °C (32 to 158° F); no freezing

Air temperature

-10 to 80° C (14 to 176° F)

Materials

Hydrocarbon resistant polymers, 316 stainless steel

Dimensions

Sensor: Ø: 160 mm (6.3 in), guiding cage: Ø: 180 mm (7.1 in)

Integral cable

10 m (~33 ft.) supplied with sensor, 3 x 18 AWG, blue PVC jacket

CERTIFICATION

ATEX Intrinsically Safe: II1G Ex ia IIC T4 Ga -40 °C to +70 °C. Also: IECEx and CETLUS

Combined with PS220/N4, approved for operation in hazardous location.

Performance

EPA - Conforms to Spill Prevention, Control and Countermeasure (SPCC) - Oil Pollution
Prevention regulation (40 CFR part 112), and EPA/530/UST-90/009 - Leak Detection Methods
TÜV - Type approval in accordance with WHG (Water Resources Law) § 19 h

Manufacture

ISO 9001:2015 Certified

ACCESSORIES

Integral Stiller

Anti-submersion air pocket

  

Specifications vary for other sub-models - please enquire