Portable humidity and temperature measurement
HygroPalm22-A
portable spot checks
compatible with all HC2 probes
all psychrometric calculations
Portable humidity and temperature measurement.
This handheld device can be used in combination with any of the HygroClip HC2 probes, using AirChip technology to offer outstanding accuracy and repeatability performance. The range of HC2 probes, and the ability to calculate humidity in a variety of different scales (see below), allows the HygroPalm22-A (HP22-A) to be extremely versatile.
Quick spot checks of processes or controlled areas can be made to ensure humidity and temperature requirements are within acceptable limits.
This portable unit can be used to decrease measurement costs by using a single instrument to monitor several locations, when permanent monitoring is either not required or cannot be justified.
The HP22-A can also be used to cross-check permanently installed systems.
For an option with an internal data logger or two probes connected simultaneously see the HygroPalm23-A
The HP22-A calculates humidity in a choice of humidity scales:
- Relative humidity in %
- Temperature in °C or °F
- Absolute humidity in Kg/m3
- Dew point/frost point in °C or °F
- Wet-bulb temperature in °C
- Enthalpy in KJ/Kg
- Specific humidity in g/Kg
- Vapour concentration in g/m3
- Mixing ratio in g/Kg
- Saturation vapour pressure in hPa
- Partial water vapour pressure in hPa
- Water vapour saturation pressure in hPa
- Water vapour partial pressure
Sensor Technology
Advanced sensor diagnostics can be enabled using the AirChip3000 technology enbedded in the HygroClip2 (HC2) probe. Up to 2,000 measured values can be stored in the probe with the ability to set alarm limits, configure measuremnent intervals and download the data to HW4 software.
For further information about humidity measurement and hygrometry issues, please visit our Masterclass section.
GENERAL |
||||
Measurement |
Relative humidity and temperature |
|||
Measurement principle |
Rotronics rh probe and Pt100 |
|||
Measuring range with interchangeable probe |
0 to 100 %rh and -50 to 200 °C |
|||
Number of probe inputs |
1 |
|||
Probe type |
All ROTRONIC HC2 probes |
|||
Max. probe cable length |
Passive: 5 m Active: 100m |
|||
Probe Initialisation time |
Typically <2 sec |
|||
Resolution |
Airchip 3000 <0.02%rh and 0.01K |
|||
Response time t 63 |
Probe dependent |
|||
Accuracy at 23 ±5 °C |
Probe dependent |
|||
Operational temp. and humidity range (instrument) |
0 to 100 % rh and -10 to 60 °C |
|||
Long term stability |
<1 %rh / year |
|||
Allowed flow rate |
Probe dependent |
|||
Probe diagnostics (drift,state) |
Programmable, default:off |
|||
Display and Communications |
||||
Display type |
Backlit graphical LCD (configurable) |
|||
Psychrometric calculations |
All psychrometric values |
|||
Battery indicator |
Low battery display |
|||
Trend indicator |
Yes |
|||
Statistical functions |
Min / max, average |
|||
Measurement interval |
Typically 1 sec without calculations |
|||
Start-up time |
Typically 3 Seconds |
|||
Data logging |
2000 data point memory in probe |
|||
PC interface |
Via interface cable and HW4 software |
|||
Calibration Adjustment |
||||
Probe adjustment by keypad |
Multipoint |
|||
Probe adjustment by software |
Via HW4 software and service cable. rh: multipoint, temperature 2 point |
|||
Event logging |
System related events (FDA, GAMP) |
|||
Firmware update |
With internet or HW4 software |
|||
User information |
from Software HW4 (device manager) |
|||
Data processing via HW4 |
Yes |
|||
Device protection via password |
Yes |
|||
Sensor diagnostics (drift, state) |
Programmable; factory default - Off |
|||
Max. cable length service cable |
5 m |
|||
Firmware update |
Via HW4 software and service cable |
|||
Certification |
||||
CE |
Compliant, 2007/108/EG |
|||
IP protection rating |
IP40 |
|||
Fire protection class |
Complies UL94-HB |
|||
Audit trail and electronic records |
FDA 21 CFR Part 11 & GAMP compliant |
|||
Shipping |
||||
Shipping weight |
210 g |
|||
MECHANICAL |
||||
Dimension |
196H (without probe) 268H (with stanard probe)x 72W x 35D mm |
|||
Material |
Housing: ABS |
|||
ELECTRICAL |
||||
Power |
9 V battery or power supply |
|||
Power consumption |
4 mA consumption with back light off |
|||
Outputs |
||||
Service interface |
Mini USB (UART) |
|||
All specifications subject to change |
TYPICAL ACCESSORIES |
||
|
Handheld Instrument Set |
|
Service Cables |
||
Extension CableE2-02A black, 2 m |
||
Filtercarrier & filter for standard probe HC2-SNSP-PCB-PE40 gray |
||
Push-on calibration deviceER-15 Ø14…15 mm; gasket with O-ring and thumb screw; for 1 probe; brass, nickel-plated |
||
Desktop stand for handheld instrumentsDESK-HP |
||
Humidity standards |
MANUALS:
Handheld relative humidity and temperature measurement HP22-A manual
CALCULATORS AND CONVERSION CHARTS:
TECHNICAL BULLETINS:
Explanation of relative humidity
DATASHEET:
Handheld relative humidity and temperature measurement HP22-A datasheet