Oil in water analyser able to determine oil types and other species
EX-100M-1000M
side stream flow
automatic ultrasonic cleaning
water composition analysis
rapid speed of response
Improved oil in water measurements.
Significant steps have been taken to improve oil in water measurements. Systems from Advanced Sensors have been able to operate in the field for many years with zero maintenance. IMA can support their claim to be the world's best oil in water analyser. Besides monitoring oil in water from low ppb to 20,000 ppm, the EX-1000M can automatically determine the type of oil that is being detected, as well as making solids measurements such as sand content of water. Both of these features are useful in monitoring water pollution.
The use of an automatic ultrasonic cleaning method allows the EX-1000M to provide reliable and accurate measurements for many years without requiring maintenance or consumables, making the operating costs for these systems extremely low. Many users have reported zero maintenance over several years.
The EX-100M provides an oil in water measurement via a UV fluorescence technique, while the EX-1000M includes an integral spectrum analyser. Data is logged once a second, and there is sufficient storage for 10 years of data that can be displayed quickly and easily on the graphical user interface.
Video microscopy on both the EX-100M and the EX-1000M allows solids and oil droplets to be monitored for size and quantity, greatly enhancing the usefulness of the analyser when applied to either produced fluids or produced water for re-injection.
Water composition can also be monitored using the EX-1000M. Specific process chemicals within the water can be monitored, and if the water composition changes outside of user determined limits, an alarm will alert operators.
Another unique feature of the EX-1000M is the ability to correct for different oil types. The individual spectra for different oils can be determined by the spectrometer, and correct measurement calibration can then be applied to report an accurate oil in water ppm level.
Download Oil in water product range
Microscopy
The video microscopy on both the EX-100M and the EX-1000M converts the system to monitor oil, gas and solids in one system, and also allows solids and oil droplets to be monitored for size and quantity, greatly enhancing the usefulness of the analyser when applied to either produced fluids or produced water for re-injection.
A digital camera with a magnification lens is used to capture an image. The image is then processed to find objects of interest such as oil droplets, solids and gas. Classification of particles is defined initially by sharpness and shape. Gas and oil tend to have high shape factors (spherical) where solids are less regular in shape. Gas can be distinguished from oil as it has a lower contrast in its centre than oil droplets.
A number of samples are taken and averaged to provide data for the three particle types when processed for statistical reports of particle size and total particle volume.
GENERAL |
||||
Cleaning |
Automatic ultrasonic |
|||
Sample homogenisation |
Ultrasonic |
|||
Oil droplet size |
Automatic compensation |
|||
Process temp. range |
0 to 100 °C (180 °C optional) |
|||
Process pressure range |
0 to 35 barg (180 barg optional) |
|||
Ambient temp. range |
-20 to 55 °C |
|||
Display |
Interactive touch screen |
|||
Fluorescence Specification |
||||
Measurement |
Hydrocarbons or chemicals that fluoresce |
|||
Measurement principle |
Laser induced UV fluorescence |
|||
Range |
0 to 20,000 ppm |
|||
User may select a range from 0 to 20,000 ppm |
||||
Accuracy |
± 1 % of measurement range |
|||
Repeatability |
> 99 % |
|||
Response time |
< 1 second, continuous results |
|||
Spectrometer Specification (1000 models only) |
||||
Emission wavelength range |
400 to 1,100 |
|||
Resolution |
0.5 nm |
|||
Microscopy Specification |
||||
Measurement |
Hydrocarbons, total suspended solids and gas PPM; hydrocarbons, total suspended solids and gas size; turbidity (measurement in AU) |
|||
Measurement principle |
CCD camera 2D image |
|||
Range |
Gas PPM - 0 to 1,000 ppm; Gas size - 1 to 450 um; Turbidity - 0 to 1,500 AU |
|||
Lighting |
Controlled LED lighting with 5 year MTBF |
|||
Number of images per datasheet |
1 to 50 images (user configurable) |
|||
Time between each image |
0.1 to 10 seconds (user configurable) |
|||
Imaging modes |
Flowing, static, high gas content mode |
|||
Accuracy |
Size ± 4 % of measurement range |
|||
Repeatability |
Size > 98 % |
|||
Image resolution |
2 million pixels |
|||
Calibration |
Gas PPM - 4 parameter curve fit with gain correct (microscopy PPM can auto calibrate to fluorescence measurement) Gas size - calibrated to known latex beads |
|||
Turbidity light frequency |
White light |
|||
Turbidity measurement timeline |
Every image cycle |
|||
Certification |
||||
European |
CE marked |
|||
Ingress protection |
IP66 |
|||
ATEX/IECEx |
Exd II 2G IIB T4 |
|||
CSA |
Class 1 Div 1 |
|||
Shipping |
||||
Shipping weight |
Approx. 77 Kg including stand, valve and chamber |
|||
MECHANICAL |
||||
Dimension |
1120 H x 600 W x 670 D mm (optional variants) |
|||
Clear space |
500 mm front and rear |
|||
Material (wetted parts) |
316 SS (option of hastalloy, inconel, CR25, CR 22, titanium, monel) |
|||
ATEX box |
Aluminium (316SS optional) |
|||
Sample flow rate |
0 to 25 l/min. (optional 0 to 1000 l/min.) |
|||
Ingress protection |
IP66 |
|||
Process connection |
1" ANSI flange (options available) |
|||
Viewing |
Process stream viewing window provided as standard |
|||
ELECTRICAL / UTILITIES |
||||
Power voltage |
110 or 230 VAC |
|||
Power frequency |
50 or 60 Hz |
|||
Power consumption |
60 W normal, 300 W peak |
|||
Instrument air |
5 to 8 BarG (for pneumatic valve - electrical valve optional) |
|||
Outputs |
||||
Current |
4 to 20 mA passive (modbus over HART optional) |
|||
Alarm relay 1 |
Volt free relay configurable to system alarm or ppm setpoint |
|||
Alarm relay 2 |
Volt free relay configurable to system alarm or ppm setpoint |
|||
Digital 1 |
Ethernet |
|||
Digital 2 |
2 wire ADSL |
|||
Wireless |
Wi-fi (optional) |
|||
Remote access |
VNC, master remote manager |
|||
Internal data storage |
> 10 years |
|||
All specifications subject to change |
VIDEO: